DESALINATION
PARAMETERS - 50,000 GALLON/DAY DESALINATION MODULE |
| 50,000 GALLON/DAY DESALINATION MODULE |
| |
US UNITS |
SI UNITS |
| FRESH WATER OUTPUT |
5000 gph |
18.9 m3/h |
SPECIFIC ENERGY CONSUMPTION |
MECHANICAL |
11.3 Kwh/1000 g |
3 Kwh/m3 |
| THERMAL |
47,748 BTU/1000g |
3.7 Kwh/m3 |
| AUXILIARY (PUMPS) |
.5Kwh/m3 |
.5Kwh/m3 |
| OPERATING TEMPERATURE (EVAPORATOR) |
208 F |
98 C |
| COLLECTORS EFFECTIVE AREA |
16,834 sf |
1,564 m2 |
| EVAPORATOR VESSEL |
4,490 g |
17 m3 |
| HEAT STORAGE TANK |
35,398 g |
134 m3 |
| SITE REQUIREMENTS |
17,222 sf |
1,600 m2 |
| DISTILLATE/CONCENTRATE RATIO: 65% |
DISTILLATE |
2,219 gph |
8.4 m3/hr |
| RAW WATER |
3,432 gph |
13 m3/hr |
COMPRESSOR |
POWER RATING |
60 Kw |
60 Kw |
| PRESSURE RATIO |
1.16 |
1.16 |
| VOLUME |
39,625 gpm |
150 m3/min |
| TURBINE POWER RATING |
100 Kw |
100 Kw |
| AUXILIARY START UP STEAM REACTOR |
100 Kw |
100 Kw |
| TOTAL SYSTEM THERMAL EFFICIENCY |
60% |
60% |
| WATER QUALITY |
<50 ppm |
<50 ppm |
| |
ASSUMPTIONS |
AVERAGE RADIATION |
206 BTU/sf |
650 w/m2 |
| OPERATING HOURS |
10 hr/day |
10 hr/day |
| SEA WATER |
35,000 ppm |
35,000 ppm |
| PLANT GRADIENT/AQUIFER |
32.8 |
10 m |
 |
LIFE OF INSTALLATION |
15 yrs |
15 yrs |
|
|
|